Danfoss HeatingThe Danfoss heating solutions division supplies energy-saving and comfort optimizing solutions for commercial and residential buildings worldwide. The Division's portfolio ranges from heat pumps, thermostats, burner components, electrical heating systems, floor heating, and ventilation. Lai iegūtu vairāk informācijas, veiciet nospiedienu uz attēla vai produkta virsraksta. Detalizētu informāciju par izvēlēto produktu jūs varat iegūt, lejupielādējot tehniskās dokumentācijas failu. Valves for District Heating ApplicationsDistrict heating range offers a dedicated range of motorized control valves developed especially for the high demands within district heating, both regarding the critical control of direct connected hot-water supply and primary side heat exchangers. VS 2 | | | 2-way valve designed for use in district heating, heating, hot-water service with heat exchanger or storage tank and air handling (HVAC) systems. |
Highlights - SPLIT characteristic developed for most demanding applications (DN 20 and DN 25)
- Several kVS values
- Push connection for easy mechanical connection with actuator
- Control range min. 50:1
Tehnisko datu fails : VS-2.pdf
| | | | |
VM 2 and VB 2 | | | Valves are designed for long and unproblematic performance in response to the most demanding conditions in systems such as district heating, heating, hot-water service with heat exchanger or storage tank and air handling (HVAC) systems. |
Highlights - SPLIT characteristic
- Ext. thread PN 25 (VM 2) or flanges PN 25 (VB 2)
- Suitable for water temperatures from 2 to 150°C
- Suitable for use with AMV(E) 10/20/30 and AMV(E) 13/23/33 actuators
Tehnisko datu fails : VM-2,VB-2.pdf
| | | | |
VF 2, 3 | | | Valves provide a quality, cost effective solution for most water and chilled applications. |
Highlights - DN 15-150
- kVS 0,63-320 m3/h
- PN 16
- Circulation water/glycolic water up to 50 %:
- 2 (-10*) … 130°C (DN 15-100)
- 2 (-10*) … 200°C (DN 125, 150)
- * At temperatures from -10°C up to +2°C use stem heater
- Flange PN 16 connections
- Compliance with Pressure Equipment Directive 97/23/EC
Tehnisko datu fails : VF-2,VF-3.pdf
| | | | |
VRG 2, 3 | | | Valves provide a quality, cost effective solution for most water and chilled applications. |
Highlights - DN 15-50
- kVS 0.63-40 m3/h
- PN 16
- Circulation water / glycolic water up to 50 %:
- 2 (-10*) … 130°C
- * At temperatures from -10°C up to +2°C use stem heater
- Connections:
- Compliance with Pressure Equipment Directive 97/23/EC
Tehnisko datu fails : VRG-2,VRG-3.pdf
| | | | |
VMV 3 | | | 3-way seated valve used primarily with thermohydraulic actuator ABV for flow temperature control. The valve is available with both internal and external thread. |
Highlights - DN 15-40
- kVS 2.5-12 m3/h
- PN 16
- Circulation water / glycolic water up to 30%: 2 … 120°C
- Connections:
- Internal and external thread
Tehnisko datu fails : VMV-3.pdf
| | | | |
HFE 3, 4 | | | Rotating valves can be used in systems where there is no need for defined control characteristic, and where certain amounts of leakage from closed valves can be accepted. |
Highlights - DN 20-150 (HFE 3), DN 32-150 (HFE 4)
- kvs 12-400 m3/h (HFE 3), kvs 32-400 m3/h (HFE 4)
- PN 6
- 3-way or 4-way
- Linear characteristic
- Medium temperature 2…110°C
- For mixing or diverting
- Flanged connections
Tehnisko datu fails : HFE-3,HFE-4.pdf
| | | | |
HRB 3, 4 | | | Danfoss HRB rotary valves are primarily designed for regulation of flow temperature in heating systems where a certain leakage can be accepted and where a defined control characteristic is not required. |
Highlights - DN 15-50
- kVS 0.4-40 m3/h
- PN 10
- tmax=110°C
- 3-way or 4-way
- S characteristic
Tehnisko datu fails : HRB-3,HRB-4.pdf
| | | | |
VZ 2, 3, 4 | | | VZ valves provide a high quality, cost effective solution for the control of hot and or chilled water for fan coil units, small reheaters, and recoolers in temperature control systems. |
Highlights - DN 15, 20
- kVS 0.25 - 4.0 m3/h
- PN 16
- Logarithmic flow characteristic
- Circ. water / glycolic water up to 50%: 2 … 120°C
- Reduced kvs on B port (VZ3 & VZ4 only)
- Soft sealing on plug gives complete shut-off
- Linear bypass on 3 and 4 port valves
- Valves are supplied with screwed plastic cover for manual operation
- Connections: flat end or conex
Tehnisko datu fails : VZ-2,3,4.pdf
| | | | |
VZL 2, 3, 4 | | | 2,3,4-way valve which provides a high quality, cost effective solution for the control of hot and or chilled water for fan coil units, small reheaters and recoolers in temperature control systems. |
Highlights - DN 15, 20
- kVS 0.25-3.5 m3/h
- PN 16
- Circ. water / glycolic water up to 50%: 2 … 120°C
- Reduced kVS on B port (VZL 3 & VZL 4 only)
- Soft sealing on plug gives complete shut-off
- Linear characteristic
- Linear bypass on 3 and 4 port valves
- Valves are supplied with screwed plastic cover for manual operation
- Connections: flat end or conex
- Water quality acc. to VDI 2035 requirements
Tehnisko datu fails : VZL-2,3,4.pdf
| | | | |
AMZ 112, 113 | | | Valves are typically used in connection with HVAC applications, domestic and commercial central heating applications, domestic hot water and chilled water applications, solar energy plants, priority control of hot water supply and heating (diverting function), priority control of boiler and solid fuel installations (diverting function). |
The ON/OFF zone valves can be applied together with most Danfoss Room Thermostats, particularly type RET 230 (single poled switch) and programmable Room Thermostats type TP 5000/7000. The actuator can be controlled by a SPST or SPDT switch. The limit stop switch can be used for start/stop of a fan or a circulation pump in an entirely open valve. Tehnisko datu fails : AMZ 112,113.pdf
| | | | |
Valves for Steam ApplicationsSteam range offers a full range of steam valves for steam based heating systems, humidification and sterilization. Steam applications put heavy demands to the product with high temperatures and pressures. VFS 2 | | | 2-way seated valve with logarithmic characteristic, which provides a high quality cost effective solution for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot water) and steam applications. |
Highlights - PN 25
- Flanged connections DN 15 to 100 mm
- Suitable for water or steam (max. Δp = 6 bar) 2 (-10*) to 200°C
- * At temperatures from -10 oC till +2 oC use stem heater
- Suitable for use with glycolic water up to 50 %
- Logarithmic characteristic
- Suitable for use with AMV(E) 15, 16, 25, 35, 25 SU/SD, 55, 56, 85, 86 and AMV 323, 423 or 523 actuators
- In compliance with PED directive 97/23/EC
Tehnisko datu fails : VFS-2.pdf
| | | | |
VFGS 2 | | | 2-way valve designed for use primarily in heating and district heating systems for steam applications. |
Highlights - DN 15 - 250
- Tmax. 350°C
- 2-way valve (Normaly Open)
- Medium: steam
- Cone: metal / metal sealing
- Pressure relieved
Tehnisko datu fails : VFGS-2.pdf
| | | | |
Motorized Control ValvesDistrict heating range offers a dedicated range of electrical actuators developed especially for the high demands within district heating, both regarding the critical control of direct connected hot-water supply and primary side heat exchangers. AMV(E) 10 | | | Actuators for three point control for use in district heating systems. The advanced design incorporates load related 'switch-off' to ensure that neither actuators nor valves are not exposed to overload. |
Highlights - 24 V and 230 V version
- AMV 10 spindle speed 14 s/mm
- Spring return function (DIN 32730 registration)
Tehnisko datu fails : AMV(E) 10-33.pdf
| | | | |
AMV 150 | | | Actuator is primarily designed to regulate valve in the respond to the demand of a controller in District heating, heating, floor heating, solar heating, zone heating, comfort cooling, ventilating and air conditioning systems. |
Highlights - Nominal voltage:
- 24 VAC, 50/60 Hz
- 230 VAC, 50/60 Hz
- Control input signal: 3 point
- Force: 250 N
- Stroke: 5 mm
- Speed: 24 s/mm
- Max. medium temperature: 130°C
Tehnisko datu fails : AMV 150.pdf
| | | | |
AMV(E) 20, 23 and AMV(E) 30, 33 | | | The actuators with or without safety function are available for 3-point controls. The spring return actuators can be used to provide safety shut off on power failure. |
Highlights - 224 V and 230 V version
- AMV 20, 23 - spindle speed 15 s/mm
- AMV 30, 33 - spindle speed 3 s/mm
- Spring return function (DIN 32730 registration)
Tehnisko datu fails : AMV(E) 10-33.pdf
| | | | |
AMV 323, AMV 423, AMV 523 | | | Actuators with three point control. In addition to basic functions such as manual control and position indication, the advanced design incorporates load related 'switch-off' to ensure that neither actuators nor valves are not exposed to overload. |
Features - AMV 323, spindle speed 1 s/mm
- AMV 423, spindle speed 3 s/mm
- AMV 523, spindle speed 11 s/mm
- 230/240 V and 24 V versions
- Spindle travel 0 - 50 mm
- Function extension using function modules:
- AMEK - additional switch
- AMER - P or PI controller
- AMES modulating controller Y = 0 - 10V or 0 - 20 mA
Tehnisko datu fails : AMV 323,423,523.pdf
| | | | |
AMV(E) 413, AMV(E) 610, 613, 633 | | | Actuators for three point control. The actuators are applied mainly in heating and district heating systems for water and steam up to 350°C. |
Highlights - Nominal voltage:
- 230 V / 50 Hz
- 24 V / 50 Hz
- Input signal:
- Three-point control signal:
- Modulate control signal 0(4) - 20 mA / 0(2) - 10 V
- Manual adjustment:
- Additional equipment:
Tehnisko datu fails : AMV(E) 413,610,613,633.pdf
| | | | |
AMV(E) 435 | | | Actuator is used with two and three-way valves type VRB, VRG, VF and VL up to DN 80 diameter. |
Highlights - Nominal voltage:
- 24 VAC/DC, 50 Hz/60 Hz
- 230 VAC, 50 Hz/60 Hz
- Control input signal: 3 point
- Force: 400 N
- Stroke: 20 mm
- Speed (selectable):
- Max. medium temperature: 130°C
- LED signalling
- End-position signals
- Manual operation
Tehnisko datu fails : AMV(E) 435.pdf
| | | | |
AMV(E) 55, AMV(E) 56, AMV(E) 85, AMV(E) 86 | | | The actuators are used with VFS 2 valves(AMV 55 and AMV 56 are used also with VL 2, VL 3) from DN 65 up toDN 100 diameter or with VF 2 and VF 3 DN 125 and DN 150 diameter. The actuator automatically adapts its stroke to valve end positions which reduces commisioning time. |
Highlights - The advanced design incorporates load related 'switch-off' to ensure that actuator and valve are not exposed to overload
- Digitale feedback end position indication signal for valve end position is available by terminal 4 or 5
Tehnisko datu fails : AMV(E)55,56.pdf
| | | | |
Weather CompensatorsDanfoss offers a wide range of electronic controllers for district heating and domestic hot water systems. ECL 110 | | | Universal controller for use in district heating substations and district heating systems as well as boiler-based systems with one heating circuit. |
It is an electronic controller for weather compensated flow temperature control (heating) and constant temperature control (domestic hot-water e.g.) and it is prepared for new applications by means of chip card and communication interface. The ECL Comfort 110 controller has a customdesigned display with backlight. For a quick overview, the display readouts are based on graphic symbols as well as text. The controller has triac outputs for motorized control valve and relay outputs for pumpcontrol. Tehnisko datu fails : ECL 110.pdf
| | | | |
ECL 210 | | | An electronic weather compensated temperature controller for use in district heating, central heating and cooling systems. |
Combined with the intelligent ECL application keys, the controller can control a multitude of different applications. Up to 3 circuits can be controlled. It is designed for comfortable temperatures, optimum energy consumption, easy installation by means of the ECL Application Key (Plug-and-Play) and user friendly operation. Improved energy savings are facilitated by weather compensation, adjustment of temperature according to schedule, optimization as well as limitation of return temperature, flow and power. Functionalities such as data logging and alarm functions are implemented in the controller. Tehnisko datu fails : ECL 210.pdf
| | | | |
ECL 310 | | | The ECL Comfort 310 is an electronic weather compensated temperature controller for use in district heating, central heating and cooling systems. |
It is designed for comfortable temperatures, optimum energy consumption, easy installation by means of the ECL Application Key (Plug-and-Play) and user friendly operation. Improved energy savings are facilitated by weather compensation, adjustment of temperature according to schedule, optimization as well as limitation of return temperature, flow and power. Functionalities such as data logging and alarm functions are implemented in the controller. The ECL Comfort 310 is easily operated by means of a dial (multi-functional knob) or a Remote Control Unit (RCU). The dial and the display guide the user through the text menus in the selected language. Tehnisko datu fails : ECL 310.pdf
| | | | |
SensorsThis product group comprises temperature, surface and immersion sensors with 2-wire devices. All connections are inter-changeable. ESM 10 and ESM 11 | | | ESM-10 is a room temperature and ESM-11 is a surface sensor. | | | | | |
ESMB 12 | | | Universal temperature sensor with two-wire devices and 2.5 m cable. All connections are inter-changeable. | | | | | |
ESMC | | | Surface sensor with two-wire devices and 2 m cable. All connections are inter-changeable. | | | | | |
ESMT | | | Pt 1000 outdoor sensor with two-wire devices. All connections are inter-changeable. | | | | | |
ESMU | | | Immersion sensor available in copper or stainless steel with two-wire devices. All connections are inter-changeable. | | | | | |
ECL accessories | | | For the electronic controllers ECL Comfort 210 and 310, application keys for many different application solutions are available. |
The application keys starting with 'A2xx' are used with the electronic controller ECL Comfort 210. The application keys starting with "A3xx" are used with the electronic controller ECL Comfort 310. In addition, the application keys starting with "A2xx" can also be used with ECL Comfort 310. A214Constant temperature control (heating / cooling) of ventilation systems. A217Advanced temperature control of DHW (domestic hot water) circuit with / without storage charging system. A230Weather compensated or constant flow temperature control of heating systems with sliding return temperature limitation and with / without wind compensation. A231Weather compensated flow temperature control of systems with sliding return temperature limitation. A247Weather compensated flow temperature control of systems with sliding return temperature limitation. Constant temperature control of DHW circuits with storage tank charging system. A260Weather compensated flow temperature control of heating systems with sliding return temperature limitation for two independent heating circuits. A266Weather compensated flow temperature control of heating systems with sliding return temperature limitation. Constant temperature control of DHW circuits with flow system. A361Weather compensated flow temperature control of heating systems with sliding return temperature limitation for two independent heating circuits with two pump control and refill water function. A367Weather compensated flow temperature control of heating systems with sliding return temperature limitation for two independent heating circuits. A368Weather compensated flow temperature control of heating systems with two pump control and refill water function with two pump control. Constant temperature control of DHW circuit with flow system and two pump control. A376Weather compensated flow temperature control of two independent heating systems with sliding return temperature limitation. Constant temperature control of DHW circuit with flow switch control. Tehnisko datu fails : Application Keys for ECL Comfort.pdf
| | | | |
Temperature ControllersHeating systems and subscriber stations can be equipped with the self-acting temperature controllers for domestic hot water circuits and heating circuits. RAVV | | | RAVV is self-acting thermostatic actuator primarily for use for temperature control in small hot water cylinders and to control flow temperatures in central heating systems. |
Highlights - DN 10 - 25
- Kv 0.4 - 1.6 m3/h
- PN 10 with RAV-/8 and VMT-/8 valves PN 16 with VMA valves
- Setting ranges:
- 10 … 38°C / 27 … 57°C / 40 … 70°C
- Circ. water / glycolic water up to 30%:
- 2 … 120°C with RAV-/8 and VMT-/8 valves
- 2 … 130°C with VMA valves
- Connections: Internal and external thread
- Flow mounting
Tehnisko datu fails : RAVV.pdf
| | | | |
RAVI | | | RAVI is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders - either storage type cylinders or instantaneous hot water heaters. |
Highlights - DN 10 - 25
- Kv 0.25 - 4.0 m3/h
- PN 10
- Setting range: 43 … 65°C
- Circ. water / glycolic water up to 30%:
- 2 … 90°C with KOVM valves
- 2 … 120°C with RAV-/8, VMT-/8 and VMV valves
- 2 … 130°C with VMA valves
- Connections: Internal and external thread
- Return mounting
Tehnisko datu fails : RAVI.pdf
| | | | |
RAVK | | | RAVK is self-acting thermostatic actuator primarily for use for temperature control of small hot water cylinders (e.g. storage tanks) or heat exchangers in radiator heating systems. |
Highlights - DN 10 - 25
- Kv 0.25 - 4.0 m3
- PN 10 with RAV-/8, VMT-/8 and KOVM valves, PN 16 with VMA and VMV valves
- Setting ranges:
- 25 … 45°C with VMV valves
- 25 … 65°C with RAV-/8, VMT-/8, VMA, KOVM valves
- Circ. water / glycolic water up to 30%:
- 2 … 90°C with KOVM valves
- 2 … 120°C with RAV-/8, VMT-/8 and VMV valves
- 2 … 130°C with VMA valves
- Connections: Internal and external thread
- Flow and return mounting
Tehnisko datu fails : RAVK.pdf
| | | | |
FJV | | | Self-acting temperature controllers used to control the water temperature in hot water tanks. The controllers closes on rising temperature. |
Highlights - DN 15, 20, 25
- Kvs 1.9, 3.4, 5.5 m3/h
- PN 16
- Setting range: 20 … 60°C
- Circulation water / glycolic water up to 30%: 2 … 130°C
- Connections:
- Int. thread
- Ext. thread (weld-on and ext. thread tailpieces)
Tehnisko datu fails : FJV.pdf
| | | | |
AVTB | | | Self-acting temperature controllers used to control the water temperature in hot water tanks. The controllers closes on rising temperature. |
Highlights - DN 15, 20, 25
- Kvs 1.9, 3.4, 5.5 m3/h
- PN 16
- Setting range:
- 0…30°C / 20…60°C / 30…100°C
- Circulation water / glycolic water up to 30%: -25 … +130°C
- Connections:
- Int. thread
- Ext. thread (weld-on and ext. thread tailpieces)
Tehnisko datu fails : AVTB.pdf
| | | | |
AFT 06, 17, 26, 27 | | | Thermostats operating according to the liquid expansion principle. |
AFT 06/17 have the setpoint adjuster directly fitted to the actuator; for AFT 17/27 it is delivered separately. There are two sensor designs with different time constant. Highlights - Nominal diameter: DN 15 - 125
- Nominal pressure: PN 16, 25, 40
- Type of connection: Flange
- Medium: Circulation water, waterglycol mixtures, steam
- Medium temp.: -20 to 350°C
- Flow and return mounting
- Type-tested according to DIN 3440-TR in connection with the following valves: VFG 2, VFG 21, VFGS 2, VFG 33 and VFG 34
Tehnisko datu fails : AFT 06,17,26,27.pdf
| | | | |
AVTQ | | | Self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers for instantaneous hot water production. |
Highlights - DN 15 or DN 20
- DN 15-kVS 1.6, DN 20-kVS 3.2
- PN 16 - Main valve, PN10 - Diaphragm element and pilot valve
- Suitable for domestic hot water (DHW) production in range of 45 ... 60°C
- Permanent no-load (idle) temperature (DN 15-approx. 40°C, DN 20-approx. 35°C)
- Circulation water / glycolic water up to 30% (2 … 100°C)
- Connections: Ext. thread (weld-on and thread tailpieces)
- Return mounting
SIA Inducont offers AVTQ models - AVTQ DN 15 and AVTQ DN 20 Tehnisko datu fails : AVTQ DN 15.pdf
| | | | |
AVT | | | Self-acting proportional actuator (thermostat) for temperature control developed primarily for domestic hot water (DHW) production: Hot water tanks, Storage charge systems and Instantaneous domestic hot water production. |
The AVT / VGS controller is a self-acting proportional temperature controller developed primarily for steam or hot water applications for temperatures up to 200°C. Controller closes on rising temperature. Highlights - DN 15 - 25
- Kvs 1.0 - 6.3 m3/h
- PN 25
- Setting ranges: 10 … 40°C / 20 … 70°C / 40 … 90°C / 60 … 110°C and 10 … 45°C / 35 … 70°C / 60 … 100°C / 85 … 125°C
- Temperature:
- Circ. water / glycolic water up to 30% (2 … 150°C)
- Steam 2 … 200°C
- Connections: Ext. thread (weld-on, thread and flange)
SIA Inducont offers AVT actuator in combination with VG-2 and VGS-2. Tehnisko datu fails : VG-2.pdf
| | | | |
Differential Pressure ControllersCompany offers wide range differential pressure and pressure controllers for your heating system. AVPL | | | A self-acting differential pressure controller, that can be used on primary side of house substations for smaller systems such as one and two-family houses. |
Highlights - DN 15
- Kvs 1.0, 1.6 m3/h
- PN 16
- Setting range: 0.05-0.25 bar (factory setting 0.1 bar)
- Circulation water / glycolic water up to 30% (2 … 120°C)
- Connections: Ext thread (weld-on and thread tailpieces)
Tehnisko datu fails : AVPL.pdf
| | | | |
AVP and AVP-F (PN 16) | | | A self-acting differential pressure controller primarily for use in district heating systems. The controller closes on rising differential pressure. |
highlights - DN 15-32
- kVS 0.4 - 10 m3/h
- PN 16
- Setting range (AVP): 0.05 - 0.5 bar / 0.2 - 1.0 bar / 0.8 - 1.6 bar
- Fixed setting (AVP-F): 0.2 bar / 0.3 bar / 0.5 bar
- Circulation water / glycolic water up to 30% (2 … 150°C)
- Connections: Ext. thread (weld-on, thread and flange tailpieces)
Tehnisko datu fails : AVP,AVP-F PN16.pdf
| | | | |
AVP and AVP-F (PN 25) | | | A self-acting differential pressure controller primarily for use in district heating systems. The controller closes on rising differential pressure. |
Highlights - DN 15-50
- kVS 0.4 - 25 m3/h
- PN 25
- Setting range (AVP): 0.2 - 1.0 bar / 0.3 - 2.0 bar
- Fixed setting (AVP-F): 0.2 bar / 0.5 bar
- Circulation water / glycolic water up to 30% (2 … 150°C)
- Connections:
- Ext. thread (weld-on, thread and flange tailpieces)
- Flange
Tehnisko datu fails : AVP,AVP-F PN25.pdf
| | | | |
AVD | | | A self-acting pressure reduction controller primarily for use in district heating systems. The controller has a control valve, an actuator with one control diaphragm and a spring for pressure setting. |
Highlights - DN 15-50
- kVS 0,4-25 m3/h
- PN 25
- Setting range: 1-5 bar / 3-12 bar
- Circulation water/glycolic water up to 30 % (2 … 150°C)
- Connections:
- Ext. thread (weld-on, thread and flange tailpieces)
- Flange
Tehnisko datu fails : AVD.pdf
| | | | |
AVA | | | The controller is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens on rising pressure. |
Highlights - DN 15 - 50
- kVS 4.0 - 25 m3/h
- PN 25
- Setting range: 1.0 - 4.5 bar / 3.0 - 11 bar
- Circulation water / glycolic water up to 30% (2 … 150°C)
- Connections:
- Ext. thread (weld-on, thread and flange tailpieces)
- Flange
Tehnisko datu fails : AVA.pdf
| | | | |
AVPA | | | The controller is a self-acting differential pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens on rising differential pressure. |
Highlights - DN 15 - 50
- kVS 4.0 - 25 m3/h
- PN 16, 25
- Setting range: 0.05 - 0.5 bar / 0.2 - 1.0 bar / 0.3 - 2.0 bar
- Circulation water / glycolic water up to 30% (2 … 150°C)
- Connections:
- Ext. thread (weld-on, thread and flange tailpieces)
- Flange
Tehnisko datu fails : AVPA.pdf
| | | | |
AFP | | | AFP is a self-acting differential pressure controller primarily for use in district heating systems. The controller closes on rising differential pressure. |
Highlights - DN 15 - 250
- kVS 4.0 - 400 m3/h
- PN 16, 25, 40
- Max. operating pressure: 16, 25 bar
- Temperature: 2 … 200°C
- Connections: Flange
- Flow and return mounting
Tehnisko datu fails : AFP.pdf
| | | | |
AFD | | | The controller is a self-acting pressure reducer primarily for use in district heating systems. The control closes on rising pressure. |
Highlights - DN 15-250
- PN 16, 25, 40
- Max. operating pressure 25 bar
- Max. temperature 350°C
- Water and steam applications
Tehnisko datu fails : AFD.pdf
| | | | |
AFA | | | Pressure actuator with control diaphragm and spring for pressure setting. The controller opens on rising pressure. |
Highlights - DN 15 - 250
- PN 16, 25, 40
- Max. temperature 200°C
- By-pass mounting
Tehnisko datu fails : AFA.pdf
| | | | |
AFPA | | | Pressure actuator with control diaphragm and spring for pressure setting. The controller opens on rising pressure. |
Highlights - DN 15 - 250
- PN 16, 25, 40
- Max. temperature 200°C
- By-pass mounting
Tehnisko datu fails : AFPA.pdf
| | | | |
Lodveida ventīļiThe full bore range covers ball valves with welded, flanged and flanged-welded connection possibilities. JIP-WW | | | The full bore valves with welded connection are available with handle, gear flange or worm gear. |
JIP-WW full bore ball valve with handle, worm gear or flange is an ON/OFF valve with welded connections. The valves are specially designed for district heating systems and other hot-water systems in which the water has been treated in order to avoid corrosion. The valves are also suitable for district cooling systems. Tehnisko datu fails : JIP-WW type.pdf
| | | | |
JIP-FF | | | The full bore valves with flanged connection are available with handle, gear flange or worm gear. |
JIP-FF full bore ball valve with handle, worm gear or gear flange is an ON/OFF valve with flanged connections.The valves are specially designed for district heating systems and other hot-water systems in which the water has been treated in order to avoid corrosion. The valves are also suitable for district cooling systems. Tehnisko datu fails : JIP-FF type.pdf
| | | | |
Plate Heat ExchangersBrazed plate heat exchangers type XB are made from brazed, pressed heat exchanger plates which have flow channels between them. The turbulence of the flow, and the counterflow result in effective heat transfer. Brazed Heat Exchangers with 1 Pass | | | Copper brazed stainless steel heat exchangers with one pass designed for district heating systems offer a compact design and excellent heat transfer properties. |
They are suitable for heating and domestic hot water applications and also in HVAC, cooling and industrial applications. SIA Inducont offers brazed heat exchangers with 1 pass models: XB 04, XB 06, XB 10, XB 20, XB 30, XB 37, XB 51, XB 59, XB 60, XB 61, XB 70. Tehnisko datu fails : Brazed Heat Exchanger XB.pdf
| | | | |
Brazed Heat Exchangers with 2 Pass | | | In a 1-pass exchanger all connections are placed on the same side thus making installation very easy. A 2-pass exchanger has a more compact design and can be applied in many different applications. |
Copper brazed stainless steel heat exchangers with two passes designed for district heating systems offer a compact design and excellent heat transfer properties. They are suitable for heating and domestic hot water applications, and also in HVAC, cooling and industrial applications. SIA Inducont offers brazed heat exchangers with 2 pass models: XB 04, XB 10, XB 20, XB 51. Tehnisko datu fails : Brazed Heat Exchanger XB.pdf
| | | | |
AccessoriesHere you can find the right accessories for your energy meter. Communication | | | |
L-Bus module (use for external radio) 3022072 RS232 module 3022100 RS485 module 3022101
| | | | |
Function | | | Analogue output module (4-20mA) 3022106. |
Combined module (2 pulse inputs/ 1 pulse output) 3022075 Pulse input module (2 inputs) 3022074 Pulse output module (2 outputs) 3022073
| | | | |
Supply Voltage | | | Battery 3.6 V DC (A-cell) 3022102. |
Battery 3.6 V DC (D-cell) 3022103 Mains unit 230 V AC 3022076 Mains unit 24 V AC 3022079
| | | | |
Citi šī ražotāja produkti |